Vega2790504

VEGA CNC 1270 Souter Blvd. Troy, MI 48083  (248) 585-3600

VEGA 2790500 Converter Boards

Synchro/Resolver to Encoder/Digital Converter Boards

Request a More Information

adobe

 Vega 2790500 Resolver to Digital Manual

MetanoLine02

Vega 2790500 Resolver to Digital Interface

Works with R25 and other resolvers

  • Works with R11, R25 or most any other Resolver
  • Incremental encoder output signals
  • Makes a resolver as easy to use as an encoder
  • Jumper selectable count, 1000, 1024, 2000, 2048, 4000, 4096, 8000, and 8192 A-quad-B with Index and complements
  • Jumper selectable excitation frequency including 2.5, 5.0 and 10 kHz

With the VEGA 2790500 converter you can have both the ruggedness of a resolver and the digital simplicity of the digital interface. The 2790500 may be used with almost any resolver. The Index/Marker pulse (Channel Z) will occur once per transducer cycle t the zero degree position..

MetanoLine02
2790504

Vega 2790500 Applications

  • Ideal for closed loop positioning systems
  • Machine Tools
  • Coordinate Measuring Machines
  • PLC Positioning Control
  • Index/Rotary table
  • Tracking/Telescope/Telemetry Systems
  • Transfer Lines
  • Positioning System
  • Robotic Applications
  • Dispensing Systems
MetanoLine02

Advanced Features:

  • Easy to Use and Easy to Set Up
  • Simply Retrofits
  • Panel Mount or DIN Rail option
  • Non-Phase Locked Loop Design (No Lag)
  • Highly Accurate
  • Tuned Filter For Noise Immunity
  • A-quad-B, Index and Complements
  • TTL/Line Driver Outputs
  • Quadrature encoder signals to 4 mHz
  • Single +5 vDC Supply Operation
  • Loss of Phase Detection
  • Fault Signal Output (Line Driver and Active Pull-Up)
  • Status LED's for Power, A, B, Z, Signal HI, Signal MID, and Fault
  • Configurable Fault signal conditioning for Fail-Safe operations
  • Compact Design and Easy to install

* Tracking Limited to +.25 resolver cycle in power off state

Vega 2790500 Specifications

Excitations:

2.5, 5, or 10 kHz

Resolver Input:

0.8 to 18 vpp

Power Requirements:

5 vDC @ 250 mA

Drive Capacity;

200 mA Peak

Mechanical

 2.825 x 5.25 x 1.00

Accuracy:

+/- 3 arc minutes typical

MetanoLine02

Vega 2790500 Converter Accuracy and Tracking Rate

  The tracking rate is a function of the excitation frequency and quadrature counts. With a 2.5 kHz excitation and 4000 quadrature counts the tracking rate would be 9,600 rpm. With a 10.0 kHz excitation and 4000 quadrature counts the tracking rate would be 38,400 rpm. Reducing the counts will increase the tracking rate proportionately.