VEGA CNC 1270 Souter Blvd. Troy, MI 48083  (248) 585-3600

VEGA 2785500 Converter Boards

 Synchro/Resolver to Encoder/Digital Converter Boards

Request a More Information

adobe

 Vega 2785500 Resolver to Digital Brochure

MetanoLine02

Vega 2785500 For Synchro/Resolver to Digital Applications:

Works with R11, R25 or most any Synchro/Resolver

  • Incremental encoder output signals
  • Makes synchro/resolvers as easy to use as encoders
  • Jumper Selectable line counts 250, 256, 500, 512, 1000, 1024, 2000, and 2048 A-quad-B with Index and complements
  • Jumper Selectable Excitation Frequency including 2.5, 5.0, and 10 kHz

  With the VEGA 2785500 converter you can have both the ruggedness of an Resolver and the digital simplicity of an encoder interface. The 2785500 can be used with almost any resolver. The INDEX/MARKER pulse (Channel Z) will occur once per transducer cycle at the zero degree position.

MetanoLine02

Advanced Features:

  • Easy to Use and Easy to Set Up
  • Simplify Retrofits
  • Panel Mount or DIN Rail Option
  • Fast Non-Phase Locked Loop Design (No Lag)
  • Highly Accurate
  • Tuned Filter for Noise Immunity
  • A-Quad-B, Index and Complements
  • TTL/Line Driver Outputs
  • Quadrature encoder signals to 4 mHz
  • Single +5 vDC Supply Operation
  • Loss of Phase Detection
  • Fault Signal Output (Line Driver, Open Collector, and Active Pull-Up)
  • Status LED's for Power, A, B, Z, Signal HI, Signal MID, and Fault
  • Configurable Fault signal conditioning for Fail-Safe operations
  • Compact Design and Easy to Install
MetanoLine02

Vega 2785500 Specifications

Excitations:

2.5, 5, or 10 kHz

Max Load:

250 mA

Resolver Input:

0.8 to 10 Vrms

Drive Capacity:

 200 mA

Power Requirements:

5 vDC @ 300mA

Mechanical:

2.825 x 4.75 x 1.00

Accuracy:

+/- 2 arc minutes

MetanoLine02

Vega 2785500 Converter Accuracy and Tracking Rate

  The 2785 board was designed for high speed applications. The standard converter accuracy is +/- 2 arc minutes. When using 1000 lines per excitation phase, with one phase = .1000 inch and x4 quadrature, the resolution will be .000025 inch per count with 1200 IPM the maximum tracking rate.

MetanoLine02

1270 Souter Blvd. Troy, MI 48083  (248) 585-3600